Omnidirectional Inductive Powering for Biomedical Implants

CHF 228.00
Auf Lager
SKU
VU63522H7DA
Stock 1 Verfügbar
Free Shipping Kostenloser Versand
Geliefert zwischen Mi., 29.10.2025 und Do., 30.10.2025

Details

This handbook on inductive link design investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. It is the only existing analysis on 3D inductive powering systems.


Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.

Handbook on inductive link design, in-depth theoretical analysis plus implementation Only existing analysis on 3D (omnidirectional) inductive powering systems Implementation of an inductive link for a capsule endoscope Interface study between humans and magnetic fields Includes supplementary material: sn.pub/extras

Klappentext

In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget restricts both the amount and the quality of images that can be shot. To resolve this limitation, Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Useful rectifier and inverter topologies are presented, including a class E driver that copes with coil deformations. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.


Zusammenfassung
Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.

Inhalt
Magnetic Induction.- Inductive Link Design.- Power Converters and Voltage Regulators.- Omnidirectional Coupling.- Biological Tissue Interaction.- An Inductive Power Link for a Capsule Endoscope.- A Class E Driver for Deformable Coils.- Conclusions.

Cart 30 Tage Rückgaberecht
Cart Garantie

Weitere Informationen

  • Allgemeine Informationen
    • GTIN 09781402090745
    • Genre Elektrotechnik
    • Auflage 2009 edition
    • Sprache Englisch
    • Lesemotiv Verstehen
    • Anzahl Seiten 222
    • Größe H244mm x B166mm x T19mm
    • Jahr 2008
    • EAN 9781402090745
    • Format Fester Einband
    • ISBN 978-1-4020-9074-5
    • Veröffentlichung 24.10.2008
    • Titel Omnidirectional Inductive Powering for Biomedical Implants
    • Autor Bert Lenaerts , Robert Puers
    • Untertitel Analog Circuits and Signal Processing
    • Gewicht 500g
    • Herausgeber Springer-Verlag GmbH

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.