Soil-Structure Interaction of Buried Culverts
Details
The imperfect trench installation method has been
used to reduce earth pressure on deeply buried
conduits. Few quantitative refinements to the
imperfect trench installation method, however, have
been added since the fundamental mechanics of the
reverse arching action was proposed by Marston and
Spangler. It was found during the course of this
study that significant frictional forces develop
along the sidewalls of buried conduits and adjacent
sidefills in imperfect trench installations. Current
American Association of State Highway and
Transportation Officials provisions do not consider
these frictional forces, but they cannot be neglected
in imperfect trench installations as their effect is
dominant. The objectives of this study were to study
the soil-structure interaction for deeply buried
roadway conduits (concrete pipes, corrugated
polyvinyl chloride (PVC) pipes, corrugated steel
pipes, and box culverts) and the efficiency of the
imperfect trench method for their installations.
This research identifies variables that significantly
affect earth loads, as well as the effects of bedding
and sidefill treatments.
Autorentext
PhD: Studied Structural Engineering in theDepartment of Civil Engineering at Auburn University.Postdoctoral Researcher at Auburn University.
Klappentext
The imperfect trench installation method has beenused to reduce earth pressure on deeply buriedconduits. Few quantitative refinements to theimperfect trench installation method, however, havebeen added since the fundamental mechanics of thereverse arching action was proposed by Marston andSpangler. It was found during the course of thisstudy that significant frictional forces developalong the sidewalls of buried conduits and adjacentsidefills in imperfect trench installations. CurrentAmerican Association of State Highway andTransportation Officials provisions do not considerthese frictional forces, but they cannot be neglectedin imperfect trench installations as their effect isdominant. The objectives of this study were to studythe soil-structure interaction for deeply buriedroadway conduits (concrete pipes, corrugatedpolyvinyl chloride (PVC) pipes, corrugated steelpipes, and box culverts) and the efficiency of theimperfect trench method for their installations. This research identifies variables that significantlyaffect earth loads, as well as the effects of beddingand sidefill treatments.
Weitere Informationen
- Allgemeine Informationen
- GTIN 09783639128369
- Genre Technik
- Sprache Englisch
- Anzahl Seiten 192
- Herausgeber VDM Verlag
- Größe H220mm x B150mm x T12mm
- Jahr 2009
- EAN 9783639128369
- Format Kartonierter Einband (Kt)
- ISBN 978-3-639-12836-9
- Titel Soil-Structure Interaction of Buried Culverts
- Autor Junsuk Kang
- Untertitel Application of Imperfect Trench Installation
- Gewicht 302g