The Performance of a Regenerative Heating and Cooling System
Details
This book reports on a study of the renewable energy-
based heating and cooling systems of a multipurpose
building. The first objective of the investigation
was to demonstrate the potential of solar-assisted
cooling, the second focused on the total energy
balance of the building. For base-load heating and
cooling, the building is equipped with a ground
source heat pump, supplied by a ground storage. For
solar cooling, the building is equipped with solar
collectors and two desiccant evaporative cooling
(DEC) plants. During the first year of operation,
significant problems occurred in the operation of
the DEC-plant and the heat pump. The heating energy
consumption of the building was acceptable, but the
calculated primary energy consumption was too high.
In comparison to an conventional system the
calculated CO2 saving was negative. Since user
satisfaction was high, the suboptimal operation of
the plant was not apparent to the building users.
The most important conclusion from this research
project is that without careful monitoring, the
energy-saving opportunities provided by the
installation of innovative systems may not, in
practice, be realised.
Autorentext
Diplom Wirtschaftsingenieur (FH) - Studies of
engineering and business administration University of Applied
Sciences Ingolstadt, Master of Philosophy - Institute of Energy
and Sustainable Development De Montfort University Leicester
Klappentext
This book reports on a study of the renewable energy-
based heating and cooling systems of a multipurpose
building. The first objective of the investigation
was to demonstrate the potential of solar-assisted
cooling, the second focused on the total energy
balance of the building. For base-load heating and
cooling, the building is equipped with a ground
source heat pump, supplied by a ground storage. For
solar cooling, the building is equipped with solar
collectors and two desiccant evaporative cooling
(DEC) plants. During the first year of operation,
significant problems occurred in the operation of
the DEC-plant and the heat pump. The heating energy
consumption of the building was acceptable, but the
calculated primary energy consumption was too high.
In comparison to an conventional system the
calculated CO2 saving was negative. Since user
satisfaction was high, the suboptimal operation of
the plant was not apparent to the building users.
The most important conclusion from this research
project is that without careful monitoring, the
energy-saving opportunities provided by the
installation of innovative systems may not, in
practice, be realised.
Weitere Informationen
- Allgemeine Informationen
- GTIN 09783639106275
- Genre Technik
- Sprache Deutsch
- Anzahl Seiten 152
- Herausgeber VDM Verlag Dr. Müller e.K.
- Größe H220mm x B150mm x T9mm
- Jahr 2008
- EAN 9783639106275
- Format Kartonierter Einband (Kt)
- ISBN 978-3-639-10627-5
- Titel The Performance of a Regenerative Heating and Cooling System
- Autor Achim Haller
- Untertitel System Analysis Carried out in a Multipurpose Building
- Gewicht 244g