A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability

CHF 162.35
Auf Lager
SKU
K6202K55DHU
Stock 1 Verfügbar
Geliefert zwischen Do., 22.01.2026 und Fr., 23.01.2026

Details

This book describes the design, fabrication and evaluation of a polymer-based neural interface for a cochlear electrode array, reviewed in terms of fabrication process, functionality, and reliability. Polymer-based devices have attracted attention in the neural prosthetic field due to their flexibility and compatibility with micro-fabrication process. A liquid crystal polymer (LCP) is an inert, highly water-resistant polymer suitable for the encapsulation of electronic components and as a substrate material for fabricating neural interfaces. The author has designed, fabricated, and evaluated an LCP-based cochlear electrode array for an improved polymer-based cochlear implant. The thesis deals with 3 key topics: atraumatic deep insertion, tripolar stimulation, and long-term reliability. Atraumatic insertion of the intracochlear electrode and resulting preservation of residual hearing have become essential in stateof-the-art cochlear implantation. A novel tapered design of anLCP-based cochlear electrode array is presented to meet such goals. For high-density and pitch-recognizable cochlear implant, channel interaction should be avoided. Local tripolar stimulation using multi-layered electrode sites are shown to achieve highly focused electrical stimulation. This thesis addresses another vital issue in the polymer-based neural implants: the long-term reliability issue. After suggesting a new method of forming mechanical interlocking to improve polymer-metal adhesion, the author performs accelerating aging tests to verify the method's efficacy. The aforementioned three topics have been thoroughly examined through various in vitro and in vivo studies. Verification foresees the development of LCP-based cochlear electrode array for an atraumatic deep insertion, advanced stimulation, and long-term clinical implant.



Nominated as an outstanding PhD Thesis by the Department of Electrical and Computer Engineering, Seoul National University, Korea Addresses three key topics pertaining to polymer-based neural implants: atraumatic deep insertion, tripolar stimulation, and long-term reliability Describes the design, fabrication, and evaluation of LCP-based cochlear electrode array for an improved polymer-based cochlear implant

Autorentext
Dr. Tae Mok Gwon was a member of the NanoBio-electronics & Systems Laboratory, Department of Electrical and Computer Engineering, Seoul National University, Korea. He is currently a Senior engineer at Semiconductor R&D center, Samsung Electronics Co., Ltd..


Inhalt

Abstract.- Contents.- List of Figures.- List of Tables.- List of Abbreviations.- Chapter 1 Introduction.- 1.1 Overview of Neural Prostheses and Cochlear Implants.- 1.2 Review of Cochlear Electrode Arrays.- 1.3 Proposed Polymer Cochlear Electrode Array.- 1.4 Long-Term Reliability of Polymer-Based Neural Prostheses.- 1.5 Objectives of the Dissertation.- Chapter 2 Materials and Methods.- 2.1 Liquid Crystal Polymer (LCP).- 2.2 Cochlear Electrode Array for Atraumatic Deep Insertion.- 2.3 Polymer Electrode Array for Tripolar Stimulation.- 2.4 Long-Term Reliability Analysis of LCP-Based Neural Implants.- Chapter 3 Results.- 3.1 LCP-Based Cochlear Electrode Array for Atraumatic Deep Insertion.- 3.2 Polymer Electrode Array for Tripolar Stimulation.- 3.3 Long-Term Device Reliability.- Method.- Chapter 4 Discussion.- 4.1 LCP-Based Cochlear Electrode Arraysfor Atraumatic Deep Insertion.- 4.2 Power Consumption and Stimulation Threshold of Tripolar Stimulation.- 4.3 Technical Strategies toImprove Device Reliability.- 4.4 Review of Long-Term Reliability of LCP-Based Devices.- Chapter 5 Conclusion.- References. <p

Weitere Informationen

  • Allgemeine Informationen
    • GTIN 09789811304712
    • Genre Elektrotechnik
    • Auflage 2018 edition
    • Sprache Englisch
    • Lesemotiv Verstehen
    • Anzahl Seiten 88
    • Größe H241mm x B156mm x T15mm
    • Jahr 2018
    • EAN 9789811304712
    • Format Fester Einband
    • ISBN 978-981-1304-71-2
    • Veröffentlichung 04.06.2018
    • Titel A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability
    • Autor Tae Mok Gwon
    • Untertitel Springer Theses
    • Gewicht 334g
    • Herausgeber Springer-Verlag GmbH

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.
Made with ♥ in Switzerland | ©2025 Avento by Gametime AG
Gametime AG | Hohlstrasse 216 | 8004 Zürich | Schweiz | UID: CHE-112.967.470