Balancing Exhaust Ventilation Systems
Details
Dampers are used to adjust the distribution of
airflows in duct systems. The common (i.e., most
commonly used) method is to adjust each damper in
turn so that the airflow through its branch equals
the desired level. Typically, the airflow through
each branch duct is estimated from the centerline
velocity pressure. To test the effectiveness of that
approach, dampers were adjusted on a seven branch,
full-sized experimental duct system. After adjusting
the dampers for a given condition, the percent
excess airflow (%Qexcess) for the system was
estimated as the amount above the ideal fan airflow
that would exist if the fan speed were adjusted so
that the lowest ratio of airflow to airflow goal for
any branch was unity. The lower the value of percent
excess airflow, the more perfectly balanced the
system was. The results varied with the level of the
target airflows. The excess airflow values were much
higher than the airflow values found by Dodrill
(2004) on the same system for the SPh Goal Ratio
method proposed by Guffey (2005). This analysis
should be useful to professionals in the fields of
HVAC and ventilation design.
Autorentext
Vivek is a Senior Manager in process and operational excellence in the financial services sector. He has a Master's in Industrial Management Systems Engineering, a Bachelor's in Mechanical Engineering and a Six Sigma Master Black Belt certification. He has extensive academic research experience in exhaust ventilation systems.
Klappentext
Dampers are used to adjust the distribution of airflows in duct systems. The "common"(i.e., most commonly used) method is to adjust each damper in turn so that the airflow through its branch equals the desired level. Typically, the airflow through each branch duct is estimated from the centerline velocity pressure. To test the effectiveness of that approach, dampers were adjusted on a seven branch, full-sized experimental duct system. After adjusting the dampers for a given condition, the percent excess airflow (%Qexcess) for the system was estimated as the amount above the ideal fan airflow that would exist if the fan speed were adjusted so that the lowest ratio of airflow to airflow goal for any branch was unity. The lower the value of percent excess airflow, the more perfectly balanced the system was. The results varied with the level of the target airflows. The excess airflow values were much higher than the airflow values found by Dodrill (2004) on the same system for the "SPh Goal Ratio" method proposed by Guffey (2005). This analysis should be useful to professionals in the fields of HVAC and ventilation design.
Weitere Informationen
- Allgemeine Informationen
- GTIN 09783639120301
- Sprache Englisch
- Genre Technik
- Anzahl Seiten 72
- Größe H220mm x B220mm
- Jahr 2009
- EAN 9783639120301
- Format Kartonierter Einband (Kt)
- ISBN 978-3-639-12030-1
- Titel Balancing Exhaust Ventilation Systems
- Autor Vivek Balasubramanian
- Untertitel Effectiveness of the Common Method in Balancing Exhaust Ventilation Systems
- Herausgeber VDM Verlag