Cancer Incidence Risks and Patient Dose Due to Fluoroscopic Procedures

CHF 67.55
Auf Lager
SKU
U25IJ043S5D
Stock 1 Verfügbar
Free Shipping Kostenloser Versand
Geliefert zwischen Mi., 15.10.2025 und Do., 16.10.2025

Details

Cancer incidence risk, organ and effective dose of ninety (90) patients undergoing selected fluoroscopic procedures have been estimated. Organ and effective dose were estimated using Monte Carlo Code (PCXMC) with air kerma as input. Excess relative risk of site specific solid cancer and all solid cancers excluding thyroid and Non-melanoma skin cancers incidences were estimated using Biological Effects of Ionising Radiation VII Committee risk models. The mean effective dose was found to be 0.29 ± 0.07, 0.84 ± 0.13, 3.15 ± 0.44, 6.24 ± 0.7, 0.38 ± 0.05 mSv for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations respectively. Longer radiation beam on time, high number of radiographs taken per patient and wide exposure beam area on the surface of the patient was found to contribute to increased doses in patient. Cancer incidence in patients of the same age was higher in women than in men except cancer of the colon which had higher incidence in men than in women and cancer of the liver which had equal incidences. Younger patients have a higher risk of incurring any type of cancer due to radiation exposure than older patients.

Autorentext

He obtained his B.Sc. degree in Physics at the Kwame Nkrumah University of Science and Technology, Kumasi, Ghana in 2005. He pursued Master of Philosophy degree in Radiation Protection at the University of Ghana, Accra and which was awarded in 2008. Mr. Gyekye is a research scientist at the Radiation Protection Inst.,Ghana Atomic Energy Commission.

Cart 30 Tage Rückgaberecht
Cart Garantie

Weitere Informationen

  • Allgemeine Informationen
    • Sprache Englisch
    • Gewicht 213g
    • Untertitel Emphasis on the Barium Series, Myelogram and Urethrogram Examinations
    • Autor Prince Kwabena Gyekye , Mary Boadu , Johnson Yeboah
    • Titel Cancer Incidence Risks and Patient Dose Due to Fluoroscopic Procedures
    • ISBN 978-3-659-18119-1
    • Format Kartonierter Einband (Kt)
    • EAN 9783659181191
    • Jahr 2012
    • Größe H220mm x B150mm x T8mm
    • Herausgeber LAP Lambert Academic Publishing
    • Anzahl Seiten 132
    • Auflage Aufl.
    • Genre Ratgeber & Freizeit
    • GTIN 09783659181191

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.