CFD Simulation of Airflow Distribution with Active Chilled Beam AC

CHF 49.90
Auf Lager
SKU
TAVK9LT9AMK
Stock 1 Verfügbar
Geliefert zwischen Mo., 20.04.2026 und Di., 21.04.2026

Details

Chilled beam air-conditioning technology evolved in Europe in the late 1970s. These systems are supposedly more energy efficient and are claimed to be reducing electricity usage by about 20-30% because of reduced fan power requirement. It is designed based on the concept of nozzles. The primary airflow coming from the ducts pass through nozzles inside the beam unit to create a high velocity jet which in turn creates a low pressure region and induces part of the room air into the air-conditioning unit. This induced air is cooled and then mixed with primary air which is sent back for air conditioning. Because of the reduced fan power requirement to pump the air, the chilled beam unit turns out to be energy efficient. The objective of this research was to investigate the air velocity and temperature distribution inside a room fitted with two active chilled beams using the commercial CFD solver-FLUENT. Numerical results have been validated by velocity measurements obtained from TROX DID 612B-HC active chilled beam selection program. The results obtained from the numerical simulations agreed well with the empirical data available from the TROX selection program.

Autorentext

The author was born in 1988 in Vijayawada,India. He received his B.Tech in Mechanical Engg from JNTU-Hyderabad in 2009 and M.S(Thesis) in Mechanical Engg from the University of Florida in 2011.After graduation,he joined Ford Motor Company as a CFD Engineer. He wants to be an entrepreneur in the future and start up his own CFD consulting firm.

Weitere Informationen

  • Allgemeine Informationen
    • GTIN 09783659192661
    • Auflage Aufl.
    • Sprache Englisch
    • Genre Maschinenbau
    • Anzahl Seiten 76
    • Größe H4mm x T4mm
    • Jahr 2012
    • EAN 9783659192661
    • Format Kartonierter Einband (Kt)
    • ISBN 978-3-659-19266-1
    • Titel CFD Simulation of Airflow Distribution with Active Chilled Beam AC
    • Autor Abhijyoth Reddy Vempati , Herbert A. Ingley
    • Untertitel CFD Investigation Of Air Velocity & Temperature Distribution In A Room Equipped With Active Chilled Beam Air-Conditioner
    • Herausgeber LAP Lambert Academic Publishing

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.
Made with ♥ in Switzerland | ©2025 Avento by Gametime AG
Gametime AG | Hohlstrasse 216 | 8004 Zürich | Schweiz | UID: CHE-112.967.470