Defective Prosthetic Heart Valves
Details
Blood flow through a defective bileaflet mechanical
heart valve was modeled using steady and pulsatile
blood flow conditions under several flow and
malfunction severity conditions. The calculations
used Reynolds-averaged Navier Stokes equations with
Newtonian blood properties. The results showed that
the flow upstream and downstream of the defective
valve is highly influenced by malfunction severity
and this resulted in a misleading improvement in the
correlation between simulated Doppler
echocardiographic and catheter transvalvular pressure
gradients. In this study, two potential non-invasive
parameters were proposed using Doppler
echocardiography and phase contrast magnetic
resonance imaging, for an early detection of
mechanical heart valve malfunction. Finally, the
relation between the coherent structures downstream
of the valve and the valve malfunction was shown and
the significant impact of valve malfunction on
platelet activation and as a consequence, on thrombus
formation was also shown.
Autorentext
Othman SMADI,Ph.D Candidate,B.Eng: Mechanical Engineering; Mosul University; Mosul;Iraq(2002).MSc: Mechanical Engineering; Jordan University of Science andTechnology; Irbid; Jordan(2005).MSc: Mechanical Engineering; Concordia University; Montreal;QC;Canada(2008).Ph.D: Mechanical Engineering; Concordia University; Montreal;QC;Canada(Currently).
Klappentext
Blood flow through a defective bileaflet mechanicalheart valve was modeled using steady and pulsatileblood flow conditions under several flow andmalfunction severity conditions. The calculationsused Reynolds-averaged Navier-Stokes equations withNewtonian blood properties. The results showed thatthe flow upstream and downstream of the defectivevalve is highly influenced by malfunction severityand this resulted in a misleading improvement in thecorrelation between simulated Dopplerechocardiographic and catheter transvalvular pressuregradients. In this study, two potential non-invasiveparameters were proposed using Dopplerechocardiography and phase contrast magneticresonance imaging, for an early detection ofmechanical heart valve malfunction. Finally, therelation between the coherent structures downstreamof the valve and the valve malfunction was shown andthe significant impact of valve malfunction onplatelet activation and as a consequence, on thrombusformation was also shown.
Weitere Informationen
- Allgemeine Informationen
- GTIN 09783639158649
- Genre Technik
- Sprache Englisch
- Anzahl Seiten 108
- Herausgeber VDM Verlag Dr. Müller e.K.
- Größe H220mm x B150mm x T6mm
- Jahr 2009
- EAN 9783639158649
- Format Kartonierter Einband (Kt)
- ISBN 978-3-639-15864-9
- Titel Defective Prosthetic Heart Valves
- Autor Othman Smadi
- Untertitel Blood flow hemodynamics and clinical complications
- Gewicht 179g