Wir verwenden Cookies und Analyse-Tools, um die Nutzerfreundlichkeit der Internet-Seite zu verbessern und für Marketingzwecke. Wenn Sie fortfahren, diese Seite zu verwenden, nehmen wir an, dass Sie damit einverstanden sind. Zur Datenschutzerklärung.
Important tools don't forget in acute cardiotoxicity management
Details
This study showed that:- The majority of the studied patients (94%) survived and (6%) of the patients died. - ECG test sensitivity was 100%, specificity was 46.8%, PPV of ECG was 10.7% and NPV was 100%.- MAS score, GCS score, and serum cTnI were very highly significantly increased with death hence could be used as predictors for the mortality.- Serum CK-MB couldn't be used as an outcome predictor.- Serum cTnI>1.0ng/ml had sensitivity 100% and specificity 89.4% and NPV 100% with excellent diagnostic characteristic (accuracy rate 96.4%).- GCS at cut off 10 had corresponding sensitivity 100% and specificity 74.5% and NPV 100% with excellent diagnostic characteristic (accuracy rate 90.8%). - Performing an ECG for every patient with acute poisoning help in early recognizing the possible cardio-toxicity by simple and non-invasive tool.- The protocol of management will be the same in acute toxicity by cardiac drugs and non-cardiac toxins.
Autorentext
Dr/ Meray Medhat Shokry ZagharyLecturer of forensic and clinical toxicology in Faculty of Medicine, Sohag University, Sohag, EgyptDoctorate degree MD in clinical toxicologyMember of American Academy of clinical toxicology (AACT).
Klappentext
This study showed that: The majority of the studied patients (94%) survived and (6%) of the patients died. ECG test sensitivity was 100%, specificity was 46.8%, PPV of ECG was 10.7% and NPV was 100%. MAS score, GCS score, and serum cTnI were very highly significantly increased with death hence could be used as predictors for the mortality. Serum CK-MB couldn t be used as an outcome predictor. Serum cTnI>1.0ng/ml had sensitivity 100% and specificity 89.4% and NPV 100% with excellent diagnostic characteristic (accuracy rate 96.4%). GCS at cut off 10 had corresponding sensitivity 100% and specificity 74.5% and NPV 100% with excellent diagnostic characteristic (accuracy rate 90.8%). Performing an ECG for every patient with acute poisoning help in early recognizing the possible cardio-toxicity by simple and non-invasive tool. The protocol of management will be the same in acute toxicity by cardiac drugs and non-cardiac toxins.
Weitere Informationen
- Allgemeine Informationen
- GTIN 09786139472390
- Sprache Englisch
- Genre Medical Books
- Größe H220mm x B150mm x T8mm
- Jahr 2022
- EAN 9786139472390
- Format Kartonierter Einband
- ISBN 6139472393
- Veröffentlichung 28.04.2022
- Titel Important tools don't forget in acute cardiotoxicity management
- Autor Meray Medhat Shokry Zaghary
- Untertitel ECG, cardiac troponin I, GCS, MAS how can be important when you evaluate acute cardiotoxic patient
- Gewicht 197g
- Herausgeber LAP LAMBERT Academic Publishing
- Anzahl Seiten 120