Microdosimetric Response of Physical and Biological Systems to Low- And High-Let Radiations

CHF 247.95
Auf Lager
SKU
OVIQRDDQ1F7
Stock 1 Verfügbar
Geliefert zwischen Mi., 24.12.2025 und Do., 25.12.2025

Details

Informationen zum Autor Professor Horowitz is the world-reknown expert on TL theory and applications to dosimetry. He is the author of the highly successful 3 volume book on TLD and TLD dosimetry, has authored approximately 150 research papers and fifteen review articles on TLD and the microdosimetric aspects of TL mechanisms. Prof. Horowitz is on the Editorial Board of three leading radiation-dosimetry- related international journals. In the past two decades he has pioneered and developed microdosimetric TL models such as the Unified Interaction Model, The Extended track Interaction Model and Modified track Structure Theory models for the calculation of TL efficiency. All co-authors are also internationally recognised scientists in their fields of expertise, Five of the eight are professors at highly rated universities and have had extensive experience in writing and editing books, conference proceedings, review articles, graduate student training, etc Klappentext One of the aims of this book was to focus the attention of specialists to the diversity of the effects of the ionising radiation on biological and physical systems. Special emphasis has been placed on the exquisite complexities/differences introduced by high ionisation density versus low ionisation density irradiation in both biological and physical systems (Scholz - Chapter 1, Horowitz - Chapter 2, Olko - Chapter 3). As well we wanted to point out the need for novel experimental and theoretical approaches required to advance the important fields of micro and nanodosimetry. Important first steps have already been taken, for example, the accelerated application of semiconductor detectors in their various forms to microdosimetry and as well to practical, important applications in the radiation dosimetry of oncological procedures (Rosenfeld - Chapter 6). The vast number of applications of TLD to radiation dosimetry are not neglected; a special chapter is devoted to the application of TLDs to medical dosimetry applications (Mobit and Kron - Chapter 7) as well as a tutorial approach in an additional chapter to the cavity theories required to extrapolate dose from the detector medium to the tissue medium (Mobit and Sandison - Chapter 5). One of the major features of this book is the intensive, in depth, coverage of the theory and modelling of TL both from the solid state physics point of view (Chen - Chapter 4) and the microdosimetic point of view (Horowitz - Chapter 2 and Olko - Chapter 3). The many puzzling, quaint, quizzical features of TL science can now be understood in the framework of these advanced theoretical models, explained in straightforward, understandable terms.Aims to focus the attention of specialists to the diversity of the effects of the ionising radiation on biological and physical systems. This work places emphasis on the exquisite complexities/differences introduced by high ionisation density versus low ionisation density irradiation in both biological and physical systems. Inhaltsverzeichnis 1. Dose Response of Biological Systems to Low- and High-LET Radiation (M. Scholz) 2. A Unified and Comprehensive Theory of the TL Dose Response of Thermoluminescent Systems Applied to LiF:Mg, Ti (Y. Horowitz) 3. Microdosimetric Interpretation of Photon Energy Response in TL Systems (P. Olko) 4. Dose Dependence of Thermoluminescence (TL) and Optically Stimulated Luminescence with Uniform Excitation (R. Chen) 5. Cavity Theory (P. Mobit and G. Sandison) 6. Semi-Conductor Radiation Detectors in Modern Radiation Therapy (A.B. Rosenfeld) 7. Applications of Thermoluminescent Dosemeters in Medicine (P. Mobit and T. Kron)...

Autorentext
Professor Horowitz is the world-reknown expert on TL theory and applications to dosimetry. He is the author of the highly successful 3 volume book on TLD and TLD dosimetry, has authored approximately 150 research papers and fifteen review articles on TLD and the microdosimetric aspects of TL mechanisms. Prof. Horowitz is on the Editorial Board of three leading radiation-dosimetry- related international journals. In the past two decades he has pioneered and developed microdosimetric TL models such as the Unified Interaction Model, The Extended track Interaction Model and Modified track Structure Theory models for the calculation of TL efficiency. All co-authors are also internationally recognised scientists in their fields of expertise, Five of the eight are professors at highly rated universities and have had extensive experience in writing and editing books, conference proceedings, review articles, graduate student training, etc

Klappentext

One of the aims of this book was to focus the attention of specialists to the diversity of the effects of the ionising radiation on biological and physical systems. Special emphasis has been placed on the exquisite complexities/differences introduced by high ionisation density versus low ionisation density irradiation in both biological and physical systems (Scholz - Chapter 1, Horowitz - Chapter 2, Olko - Chapter 3). As well we wanted to point out the need for novel experimental and theoretical approaches required to advance the important fields of micro and nanodosimetry. Important first steps have already been taken, for example, the accelerated application of semiconductor detectors in their various forms to microdosimetry and as well to practical, important applications in the radiation dosimetry of oncological procedures (Rosenfeld - Chapter 6). The vast number of applications of TLD to radiation dosimetry are not neglected; a special chapter is devoted to the application of TLDs to medical dosimetry applications (Mobit and Kron - Chapter 7) as well as a tutorial approach in an additional chapter to the cavity theories required to extrapolate dose from the detector medium to the tissue medium (Mobit and Sandison - Chapter 5). One of the major features of this book is the intensive, in depth, coverage of the theory and modelling of TL both from the solid state physics point of view (Chen - Chapter 4) and the microdosimetic point of view (Horowitz - Chapter 2 and Olko - Chapter 3). The many puzzling, quaint, quizzical features of TL science can now be understood in the framework of these advanced theoretical models, explained in straightforward, understandable terms.


Zusammenfassung
Aims to focus the attention of specialists to the diversity of the effects of the ionising radiation on biological and physical systems. This work places emphasis on the exquisite complexities/differences introduced by high ionisation density versus low ionisation density irradiation in both biological and physical systems.

Inhalt

  1. Dose Response of Biological Systems to Low- and High-LET Radiation (M. Scholz)
    1. A Unified and Comprehensive Theory of the TL Dose Response of Thermoluminescent Systems Applied to LiF:Mg, Ti (Y. Horowitz)
    2. Microdosimetric Interpretation of Photon Energy Response in TL Systems (P. Olko)
    3. Dose Dependence of Thermoluminescence (TL) and Optically Stimulated Luminescence with Uniform Excitation (R. Chen)
    4. Cavity Theory (P. Mobit and G. Sandison)
    5. Semi-Conductor Radiation Detectors in Modern Radiation Therapy (A.B. Rosenfeld)
    6. Applications of Thermoluminescent Dosemeters in Medicine (P. Mobit and T. Kron)

Weitere Informationen

  • Allgemeine Informationen
    • GTIN 09780444516435
    • Genre Physics
    • Editor Horowitz Yigal
    • Anzahl Seiten 500
    • Herausgeber Elsevier Science & Technology
    • Größe H240mm x B165mm x T23mm
    • Jahr 2006
    • EAN 9780444516435
    • Format Fester Einband
    • ISBN 978-0-444-51643-5
    • Veröffentlichung 07.06.2006
    • Titel Microdosimetric Response of Physical and Biological Systems to Low- And High-Let Radiations
    • Autor Yigal (Ben Gurion University, Physics De Horowitz
    • Untertitel Theory and Applications to Dosimetry
    • Gewicht 1030g
    • Sprache Englisch

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.
Made with ♥ in Switzerland | ©2025 Avento by Gametime AG
Gametime AG | Hohlstrasse 216 | 8004 Zürich | Schweiz | UID: CHE-112.967.470