optimal amount of refrigerant in a refrigeration system

CHF 57.55
Auf Lager
SKU
TFQTOCGN8BF
Stock 1 Verfügbar
Geliefert zwischen Mi., 29.04.2026 und Do., 30.04.2026

Details

Determination of the optimal amount of refrigerant in field assembled refrigeration systems by use of a sight glass installed in liquid line is often misleading and unreliable. This is attributed to interferences to laminar flow of the refrigerant in the sight glass by ice formation in the expansion valve, vaporization of the liquid in pipes and foreign particles. Due to these interferences refrigeration systems may be overcharged or undercharged with the refrigerant. Measurement of temperatures and pressures at the inlet and exit of an evaporator may provide an accurate and reliable criterion of establishing the optimal amount of refrigerant in a refrigeration system. Using Rayleigh's method of dimensional analysis, a mathematical model that expresses the evaporator cooling rate for field assembled refrigeration systems in terms of physical properties of the evaporator and the thermodynamic properties of refrigerant R134 a was developed. The model expresses the optimal amount of refrigerant in a refrigeration system corresponding to the maximum cooling rate.

Autorentext

Mr. Patrick Wainaina holds a Master of science degree in Industrial Systems Engineering Energy option from Egerton University in Nakuru Kenya. He is currently a lecturer of plant engineering in the department of mechanical engineering department in Kinyanjui Technical Institute in Nairobi Kenya.

Weitere Informationen

  • Allgemeine Informationen
    • GTIN 09783844312591
    • Sprache Englisch
    • Genre Maschinenbau
    • Anzahl Seiten 76
    • Größe H220mm x B150mm x T5mm
    • Jahr 2011
    • EAN 9783844312591
    • Format Kartonierter Einband
    • ISBN 3844312595
    • Veröffentlichung 02.03.2011
    • Titel optimal amount of refrigerant in a refrigeration system
    • Autor Patrick Wainaina
    • Untertitel optimal amount of refrigerant in a refrigeration system by a mathematical model for maximum cooling
    • Gewicht 131g
    • Herausgeber LAP LAMBERT Academic Publishing

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.
Made with ♥ in Switzerland | ©2025 Avento by Gametime AG
Gametime AG | Hohlstrasse 216 | 8004 Zürich | Schweiz | UID: CHE-112.967.470
Kundenservice: customerservice@avento.shop | Tel: +41 44 248 38 38