VFTO studies due to switching operations in 132 KV GIS Substation

CHF 57.55
Auf Lager
SKU
QMA3DCG980R
Stock 1 Verfügbar
Geliefert zwischen Do., 26.02.2026 und Fr., 27.02.2026

Details

In a Gas insulated substations, the operation of disconnector switches and circuit breakers can cause Very Fast Transient Over voltages (VFTOs), which will bring an instantaneous change in voltage with a very short rise time and it is normally followed by oscillation having high frequencies. For designing the insulation level of a substation, it is essential to know the maximum value of VFTO. Fast operating disconnector switches are usually used to reduce time of the breakdown; however, it cannot eliminate fully the effect of the VFTO. This Book results the most accurate results of Very Fast Transient over Voltages of 132 KV transformer caused by the switching operation. A 132KV transformer is designed using EMTP-RV simulin, the VFTOs generated by the switching operations have been analyzed and are presented. The VFTOs generated due to Disconnector switching operation can cause insulation failure at very high voltage levels. The reasons of these problems are travelling waves which is generated during switching operations in a gas-insulated substation (GIS). Calculation of Very Fast Transient Overvoltage has been carried out using EMTP-RV for various switching.

Autorentext

Shohreh Monshizadeh received her Master's education in Power Electronic Engineering at the University of Islamic Azad University-South Tehran Branch also she is a professor at Electrical Engineering Department of Islamic Azad University.

Weitere Informationen

  • Allgemeine Informationen
    • GTIN 09783659795275
    • Genre Mechanical Engineering
    • Editor Azita Monshizadeh
    • Sprache Englisch
    • Anzahl Seiten 96
    • Herausgeber LAP LAMBERT Academic Publishing
    • Größe H220mm x B150mm
    • Jahr 2015
    • EAN 9783659795275
    • Format Kartonierter Einband
    • ISBN 978-3-659-79527-5
    • Titel VFTO studies due to switching operations in 132 KV GIS Substation
    • Autor Shohreh Monshizadeh
    • Untertitel Very fast transient overvoltage (VFTO) studies due to switching operations in 132 KV GIS substation

Bewertungen

Schreiben Sie eine Bewertung
Nur registrierte Benutzer können Bewertungen schreiben. Bitte loggen Sie sich ein oder erstellen Sie ein Konto.
Made with ♥ in Switzerland | ©2025 Avento by Gametime AG
Gametime AG | Hohlstrasse 216 | 8004 Zürich | Schweiz | UID: CHE-112.967.470
Kundenservice: customerservice@avento.shop | Tel: +41 44 248 38 38